Temperature measuring transducers for PT100 / PT1000 and thermocouple
|
|||
|
|||
TM1
|
|||
|
Temperature measuring with thermocouples of the type J and K and the converting to analog norm signals are possible with the thermocouple amplifiers of the series TM1 |
||
TM3
|
|||
|
The devices of the thermocouple transducer series TM3 have been developed for analyzing and converting of thermocouples type J, K, R, S, T, E, B, N into linear temperature norm signals of 0/4...20mA, 0/2...10mA resp. 0/2...10V, 0/1...5V. The build-in connectible cold junction compensation of the terminals prevents measuring errors caused by a change of the ambient temperature. The measurement range is -210...+1820°C (depending on the thermocouple which is used) and is via Dip-switch (see table 2) or USB interface (all Dip-switches position “off”) configurable by the user. The smallest measurement range is fixed at 50°C. The start temperature is in the range of -210...0°C and the end temperature 0...1820°C selectable. |
||
PT1
|
|||
|
If temperatures with PT100 or PT1000 should be converted to analog norm signals, the PT100 measuring transducers of the series PT1 come to use. |
||
PT2
|
|||
|
The devices of the series PT2 temperature-measuring transducers have been developed for linearized converting of PT100-, PT200-, PT500- resp. PT1000 signals to norm signals 0/4...20mA, 0/2...10mA resp. 0/2...10V, 0/1...5V. The module has a true 4-wire measurement. But there also sensors in 2- and 3-wire technology can be connected. At a 2-wire connection is the compensation of the wire resistance by software parameterization possible. The transducer is configurable in the range of -200…+850C, |
||
PT3
|
|||
|
The devices of the series PT1 measuring transducers have been developed for proportional converting of Pt100 or Pt1000 signals into temperature-linearised outputs of 4...20mA, current loop fed. |
||
UM1
|
|||
|
The devices of the series UM1 universal measuring transducers have been developed for analyzing and converting of PT100- resp. PT1000 signals. The modules have a true 4-wire measurement. But also sensors in 2- and 3-wire technology can be connected. The measurement range is -200…+850C, it is freely adjustable in 1C steps. The smallest measurement range is set at 50C. All necessary settings such as measurement range, switching threshold, switching hysteresis, switching performance and the output configuration can be comfortably done via an illuminated graphic display, with a resolution of 36 x 85 pixel, and buttons. Furthermore the devices have got a sensor monitoring, which is monitoring the sensor for wire breakage and short circuit. |